Purpose The transition from high Global Warming Potential (GWP) propellants such as HFA134a to low-GWP alternatives such as HFA152a and HFO1234ze(E) in pressurised metered dose inhalers (pMDIs) poses a number of challenges for inhaled pharmaceutical product development. Changes in chemicophysical properties will alter product performance, impacting in-vitro bioequivalence metrics. This study investigates those differences using equivalent pMDI hardware and formulations. Methods Aerodynamic particle size distribution (APSD) measurements, laser diffraction and high-speed imaging were used to compare the performance of HFA134a, HFA152a and HFO1234ze(E) solution formulations of beclomethasone dipropionate. Propellant-only placebos, cosolvent-free solutions, and ethanol solutions at 8% and 15% w/w were investigated. Results HFA152a formulations had increased drug deposition on the actuator and throat while HFO1234ze(E) produced comparable APSD performance to HFA134a formulations. Plumes from HFA152a formulations spread more rapidly and were less stable and repeatable than those from HFA134a. HFO1234ze(E) plumes spread more slowly than HFA134a, but converged with HFA134a ex-mouthpiece. Differences between propellants were moderated by the addition of ethanol. Conclusion Plume stability is a driver of differences between formulations in the near-orifice region. Shot-to-shot repeatability differences are more pronounced ex-mouthpiece, where mixing with ambient air is dominant. Modifications to low-GWP pMDI product actuator orifice and mouthpiece geometries may provide a route to improved in-vitro product bioequivalence relative to current pMDIs. Differences between formulations are modest and may be managed through a combination of formulation, orifice and mouthpiece geometry changes. These generic formulations provide a database of benchmark data against which the performance of low-GWP products may be compared.

Bibliographic Information

JournalPharmaceutical Research
PublisherSpringer
Publication Date2025-02-01
Publication Year2025
Volume42
Issue2
Pages385-400
Document TypeJournal Article
Print ISSN0724-8741
eISSN1573-904X
DOI10.1007/s11095-025-03830-6

Access Information

NARA Access Coverage1984-01-01~Current
Journal Homepagehttps://www.springer.com/journal/11095
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.