NARA Discovery
Article Details
← Back to Search Results
Journal Article

Characteristics of the electron beam outside the applicator in an Elekta Versa HD Linac

Kapil Dev Maharaj; Simon Goodall; Mahsheed Sabet; Joshua Dass; Mounir Ibrahim; Talat Mahmood; Pejman Rowshanfarzad
Physical and Engineering Sciences in Medicine · Vol. 48, Issue 2 · pp. 635-647 · 2025

Abstract

Radiotherapy is an essential component of cancer treatment, but healthy tissues can be exposed to out-of-field doses, potentially causing adverse effects and secondary cancers. This study investigates peripheral doses outside the electron beam applicator in an Elekta Versa HD linear accelerator. Peripheral doses outside an electron applicator were measured using 6, 9, and 12 MeV beams at their respective maximum dose depths while maintaining a 100 cm source-to-surface distance. Measurements employed EBT3 films within Plastic Water DT phantoms. The influence of field size on penumbra width and peripheral doses were examined using various cutouts (6 × 6 cm², 10 × 10 cm², and a 5 cm diameter circle) within a 10 × 10 cm² applicator, with gantry and collimator angles set to 0 degrees. Additionally, the impact of collimator angles on penumbra width and peripheral doses was explored, enhancing the understanding of dose distribution. Measured profiles were also compared with those calculated using Monaco treatment planning system. Findings showed that both penumbra width and peripheral dose values increased with energy across different field sizes and collimator angles. Root Mean Square Deviation (RMSD) analysis indicated deviations of 1.8 mm for penumbra and 1.1% for peripheral doses between measured profiles and Treatment Planning System (TPS) predictions for all field sizes. Peripheral doses remained below 5% of the maximum dose at distances ranging from 10 to 15 mm away from the field edges, indicating acceptable tolerance levels (ICRU report 24). However, further dose reduction may be possible with additional shielding to keep doses as low as reasonably achievable. This study highlights the critical importance of considering peripheral doses in radiotherapy, emphasizing the need to evaluate the impact on healthy tissues outside the primary treatment area to ensure patient safety and mitigate long-term treatment-related side effects. The findings underscore the necessity of implementing appropriate measures to minimize peripheral doses.

Bibliographic Information

JournalPhysical and Engineering Sciences in Medicine
PublisherSpringer
Publication Date2025-06-01
Publication Year2025
Volume48
Issue2
Pages635-647
Document TypeJournal Article
Print ISSN2662-4729
eISSN2662-4737
DOI10.1007/s13246-025-01530-4

Access Information

NARA Access Coverage2001-01-01~Current
Journal Homepagehttps://www.springer.com/journal/13246
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.