NARA Discovery
Article Details
← Back to Search Results
Journal Article

Development and characterisation of a high-sensitivity X-ray CT polymer gel dosimeter

Jonathon Lexor Lumley; Pejman Rowshanfarzad; Mounir Ibrahim; Mario Djukelic; David J. Henry
Physical and Engineering Sciences in Medicine · Vol. 48, Issue 3 · pp. 1311-1323 · 2025

Abstract

Polymer gel dosimeters have shown potential for clinical 3D dosimetry; however, their use has been limited due to low sensitivity and reliance on scarcely available magnetic resonance imaging. This study aimed to optimise a PASSAG (Poly AMPS Sodium Salt And Gelatin) polymer gel dosimeter for X-ray computed tomography, to enhance its clinical feasibility. The total monomer concentration was increased to improve sensitivity, and different cosolvents were tested to enhance the limited solubility of N, N’-methylenebisacrylamide, the crosslinker. n-propanol was identified as the optimal cosolvent, allowing for an 18.3% monomer concentration, 30% crosslinker to total comonomer mass gel, at a 3:7 cosolvent-to-water ratio. The optimised formulation, PASSAG-N (PASSAG– n-propanol), consisted of 54.4% w/w deionised water, 23.3% n-propanol, 12.8% 2-acrylamido-2-methylpropane sulfonic acid sodium salt, 5.5% N, N’-methylenebisacrylamide, 4.0% gelatin, and 0.089% (4.65mM) tetrakis (hydroxymethyl)phosphonium chloride. The dosimeter was irradiated within a standard timeframe to assess its sensitivity, and theoretical calculations confirmed its equivalence to water, soft tissue, brain, and muscle. Compared to a cosolvent-free formulation, PASSAG-N exhibited a 250% increase in Hounsfield unit (HU) change, demonstrating enhanced sensitivity. The optimised gel showed a linear response over a 1–12 Gy dose range, with an average sensitivity of 1.072 ± 0.041 HU Gy⁻¹ and a dose resolution ≤ 0.31 Gy, making it a promising alternative for clinical X-ray computed tomography-based dosimetry. This study highlights the potential of PASSAG-N as a highly sensitive and potentially practical polymer gel dosimeter for clinical applications.

Bibliographic Information

JournalPhysical and Engineering Sciences in Medicine
PublisherSpringer
Publication Date2025-09-01
Publication Year2025
Volume48
Issue3
Pages1311-1323
Document TypeJournal Article
Print ISSN2662-4729
eISSN2662-4737
DOI10.1007/s13246-025-01586-2

Access Information

NARA Access Coverage2001-01-01~Current
Journal Homepagehttps://www.springer.com/journal/13246
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.