NARA Discovery
Article Details
← Back to Search Results
Journal Article

Home-Made Lateral Flow Test Strip Versus POC-CCA Assay for Detection of Active Schistosomiasis in Egypt

Manal Kamel; Faten Salah; Zeinab Demerdash; Sara Maher; Hanan El-Baz; Nahla Zakaria; Rania Abu-Shady; Amany Saad; Salwa Hassan; Doaa Abdel Aziz
Acta Parasitologica · Vol. 69, Issue 4 · pp. 1926-1936 · 2024

Abstract

Background For years, the Kato-Katz (KK) technique has been considered the gold standard for diagnosing schistosomiasis. The aim of this study was to compare the effectiveness of our previously developed gold nanoparticle-based lateral flow test strip (AuNPs-LFTS) for diagnosing active Schistosoma mansoni with that of the commercially available point-of-care Circulating Cathodic Antigen detection (POC-CCA) kit. Methods In this study, we collected sixty positive and twenty negative urine samples from patients in endemic hot spots in the Nile Delta, as well as from patients visiting the internal medicine clinic at Theodor Bilharz Research Institute (TBRI). We produced monoclonal antibodies (MAbs) against S. mansoni soluble egg antigen (SEA) from cloned hybridoma cells (4D/1D). These MAbs were conjugated with gold and mesoporous silica nanoparticles, and used to develop the LFTS. Results The LFTS demonstrated a limit of detection (LoD) of 3 ng/ml. The sensitivity and specificity of the developed LFTS were found to be 96.7% and 95%, respectively, compared to 85% and 90% for the POC-CCA detection kit. The cases were divided into groups based on egg count in the stool, categorized as light, moderate, and heavy infections. The sensitivity of the LFTS in the group with light infection was higher than that of the POC-CCA. When using the KK technique (eggs per gram of stool sample [EPG]) as the reference test, the kappa value for the nano-based strips was 0.902, compared to 0.672 for the CCA strips, indicating an almost perfect agreement between KK and our developed LFTS. Conclusion These results confirm the reliability and effectiveness of the LFTS compared to commercially available kits for rapid, sensitive, and early diagnosis of schistosomiasis. However, it is recommended to conduct further assessments of the developed strip on a larger scale with a broader range of cases before considering its introduction to local or international markets. Graphical Abstract

Bibliographic Information

JournalActa Parasitologica
PublisherSpringer
Publication Date2024-12-01
Publication Year2024
Volume69
Issue4
Pages1926-1936
Document TypeJournal Article
Print ISSN1230-2821
eISSN1896-1851
DOI10.1007/s11686-024-00917-9

Access Information

NARA Access Coverage2006-01-01~Current
Journal Homepagehttps://www.springer.com/journal/11686
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.