NARA Discovery
Article Details
← Back to Search Results
Journal Article

Insights on the Working Principles of Secondary Electrospray Ionization High-Resolution Mass Spectrometry for Quantitative Analysis of Aerosol Chemical Composition

Xin Xu; Jia Fa Zeng; Dan Dan Jin; Zheng Xu Huang; Lei Li; Anthony S. Wexler; Man Nin Chan; Zhen Zhou; Yong Jie Li; Xue Li
Aerosol Science and Engineering · Vol. 5, Issue 2 · pp. 147-155 · 2021

Abstract

Real-time mass spectrometry (MS) has attracted increasing interest in environmental analysis due to its advantages in high time resolution, minimization of sampling artifact, and avoidance of time-consuming sample pretreatment. Among real-time MS methods, secondary electrospray ionization MS (SESI-MS) is showing great promise for the detection of organic compounds in atmospheric particulate matter. In this study, we demonstrated the working principles of secondary nanoelectrospray ionization (Sec-nESI) for real-time measurement of laboratory-generated organic aerosols using l -tartaric acid (TA) as a model compound. Factors affecting the detection of TA particles using a homemade Sec-nESI source coupled with a high-resolution mass spectrometer are systematically investigated. Temperature of ion transport capillary (ITC) was found to be the key factor in determining the ion signal intensity, which shows an increase of intensity by a factor of 100 from ITC temperature of 100–300 °C and could be attributed to more efficient desolvation and ionization. The characteristic fragment ion at m / z 72.99 was selected for quantitative analysis of TA at normalized collision energy of 50%, the optimal value applied during MS/MS analysis. Detection limit of 0.14 µg/m 3 and a linear range of 0.2–2.97 µg/m 3 are achieved. Satisfactory correlations between ion signal intensity and particle surface area ( R 2 = 0.969) and mass concentration ( R 2 = 0.967) were obtained. Although an equally good correlation was observed between signal intensity and particle surface area, the good correlation between signal intensity and particle mass concentration indicates that high solubility of TA ensures efficient dissolution of TA in the primary ESI droplets for further ionization.

Bibliographic Information

JournalAerosol Science and Engineering
PublisherSpringer
Publication Date2021-06-01
Publication Year2021
Volume5
Issue2
Pages147-155
Document TypeJournal Article
Print ISSN2510-375X
eISSN2510-3768
DOI10.1007/s41810-021-00091-9

Access Information

NARA Access Coverage2017-01-01~Current
Journal Homepagehttps://www.springer.com/journal/41810
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.