Transnasal Administration of Surfactant Aerosol to the Lungs of Infants Using Direct Interfaces – Lessons Learned from Computational Fluid Dynamics

Hasan Jubaer; Dale Farkas; Caleb Dalton; Mohammad A. M. Momin; Michael Hindle; Worth Longest
Pharmaceutical Research · 2026

Abstract

Purpose Direct-to-infant (D2I) transnasal aerosol surfactant therapy (AST) offers a promising non-invasive alternative for treating neonatal respiratory distress syndrome (RDS). However, achieving high lung delivery efficiency with dry powder inhalers (DPIs) requires careful optimization of complex fluid–particle interactions. This study used computational fluid dynamics (CFD) to optimize an Infant Air‑Jet Dry Powder Aerosol Delivery System (iDP‑ADS) and derive transferable design principles. Methods A CFD model of the iDP‑ADS coupled to a 31‑week preterm nose‑throat geometry was validated against in vitro measurements. Sensitivity analyses evaluated modeling assumptions (steady‑state vs. transient, monodisperse vs. polydisperse) and critical design parameters influencing aerosol delivery, such as upstream air volume, interface geometry, temporal aerosol emission profiles, and actuation flow rates. Results The CFD model demonstrated strong in vitro agreement (2.8% mean absolute difference). Regarding modeling: standard simplifications, particularly steady-state approximations, overpredicted lung transmission (~24%), establishing the necessity of high-fidelity transient simulations with polydisperse aerosols. Regarding aerosol delivery: integrating an upstream air volume created "hydrodynamic shielding," reducing relative interface losses by up to 50%. A 10 mm diffusive path length and 20° (inward and downward) prong alignment balanced jet dissipation while minimizing nasal deposition. Front-loading of aerosol emission prevented entrapment of 10–14% of the dose in anatomical dead space. An optimal system-specific actuation flow rate of 3 L/min achieved ~53.5% aerosol lung transmission, balancing aerosolization efficiency against turbulence-driven transport losses. Conclusions High-efficiency transnasal AST requires balancing often competing aerosol generation physics, transport behavior, and clinical constraints. This study highlights CFD as a vital design tool, providing key lessons to inform future modeling and practical interface development.

Bibliographic Information

JournalPharmaceutical Research
PublisherSpringer
Publication Date2026-09-03
Publication Year2026
Document TypeJournal Article
Print ISSN0724-8741
eISSN1573-904X
DOI10.1007/s11095-026-04186-1

Access Information

NARA Access Coverage1984-01-01~Current
Journal Homepagehttps://www.springer.com/journal/11095
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.