NARA Discovery
Article Details
← Back to Search Results
Journal Article

Techniques for In Vivo Measurement of Ligament and Tendon Strain: A Review

Qiang Zhang; Naomi C. Adam; S. H. Hosseini Nasab; William R. Taylor; Colin R. Smith
Annals of Biomedical Engineering · Vol. 49, Issue 1 · pp. 7-28 · 2021

Abstract

The critical clinical and scientific insights achieved through knowledge of in vivo musculoskeletal soft tissue strains has motivated the development of relevant measurement techniques. This review provides a comprehensive summary of the key findings, limitations, and clinical impacts of these techniques to quantify musculoskeletal soft tissue strains during dynamic movements. Current technologies generally leverage three techniques to quantify in vivo strain patterns, including implantable strain sensors, virtual fibre elongation, and ultrasound. (1) Implantable strain sensors enable direct measurements of tissue strains with high accuracy and minimal artefact, but are highly invasive and current designs are not clinically viable. (2) The virtual fibre elongation method tracks the relative displacement of tissue attachments to measure strains in both deep and superficial tissues. However, the associated imaging techniques often require exposure to radiation, limit the activities that can be performed, and only quantify bone-to-bone tissue strains. (3) Ultrasound methods enable safe and non-invasive imaging of soft tissue deformation. However, ultrasound can only image superficial tissues, and measurements are confounded by out-of-plane tissue motion. Finally, all in vivo strain measurement methods are limited in their ability to establish the slack length of musculoskeletal soft tissue structures. Despite the many challenges and limitations of these measurement techniques, knowledge of in vivo soft tissue strain has led to improved clinical treatments for many musculoskeletal pathologies including anterior cruciate ligament reconstruction, Achilles tendon repair, and total knee replacement. This review provides a comprehensive understanding of these measurement techniques and identifies the key features of in vivo strain measurement that can facilitate innovative personalized sports medicine treatment.

Bibliographic Information

JournalAnnals of Biomedical Engineering
PublisherSpringer
Publication Date2021-01-01
Publication Year2021
Volume49
Issue1
Pages7-28
Document TypeJournal Article
Print ISSN0090-6964
eISSN1573-9686
DOI10.1007/s10439-020-02635-5

Access Information

NARA Access Coverage1972-01-01~Current
Journal Homepagehttps://www.springer.com/journal/10439
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.