Journal Article
Biomechanical Properties of Knee Medial Collateral Ligament Compared to Palmaris Longus for Ulnar Collateral Ligament Reconstruction
Dave Huang; Lukas Foster; Michael Stone; David Kulber; Melodie F. Metzger
Annals of Biomedical Engineering · Vol. 51, Issue 8 · pp. 1795-1801 · 2023
Abstract
Ulnar collateral ligament reconstruction (UCLR) is frequently performed among injured overhead-throwing athletes. One of the most common graft choices when performing a UCLR is the ipsilateral palmaris longus tendon (PL). The purpose of this study was to investigate the material properties of aseptically processed cadaveric knee collateral ligaments (kMCL) as a potential graft source for UCLR and compare them to the gold standard PL autograft. Each PL and kMCL cadaveric sample was subjected to cyclic preconditioning, stress relaxation, and load-to-failure testing, and the mechanical properties were recorded. PL samples exhibited a greater average decrease in stress compared to the kMCL samples during the stress-relaxation test ( p p p = 0.03 and 0.02, respectively. Both graft materials had comparable maximum toughness and demonstrated a similar ability to deform plastically without rupture. The clinical significance of our result is that prepared knee medial collateral ligament allografts may provide a viable graft material for use in the reconstruction of elbow ligaments.