NARA Discovery
Article Details
← Back to Search Results
Journal Article

Infrared Spectroscopy Can Differentiate Between Cartilage Injury Models: Implication for Assessment of Cartilage Integrity

Fatemeh Shahini; Soroush Oskouei; Ervin Nippolainen; Ali Mohammadi; Jaakko K. Sarin; Nikae C. R. te Moller; Harold Brommer; Rubina Shaikh; Rami K. Korhonen; P. René van Weeren; Juha Töyräs; Isaac O. Afara
Annals of Biomedical Engineering · Vol. 52, Issue 9 · pp. 2521-2533 · 2024

Abstract

In order to improve the ability of clinical diagnosis to differentiate articular cartilage (AC) injury of different origins, this study explores the sensitivity of mid-infrared (MIR) spectroscopy for detecting structural, compositional, and functional changes in AC resulting from two injury types. Three grooves (two in parallel in the palmar-dorsal direction and one in the mediolateral direction) were made via arthrotomy in the AC of the radial facet of the third carpal bone (middle carpal joint) and of the intermediate carpal bone (the radiocarpal joint) of nine healthy adult female Shetland ponies (age = 6.8 ± 2.6 years; range 4–13 years) using blunt and sharp tools. The defects were randomly assigned to each of the two joints. Ponies underwent a 3-week box rest followed by 8 weeks of treadmill training and 26 weeks of free pasture exercise before being euthanized for osteochondral sample collection. The osteochondral samples underwent biomechanical indentation testing, followed by MIR spectroscopic assessment. Digital densitometry was conducted afterward to estimate the tissue's proteoglycan (PG) content. Subsequently, machine learning models were developed to classify the samples to estimate their biomechanical properties and PG content based on the MIR spectra according to injury type. Results show that MIR is able to discriminate healthy from injured AC (91%) and between injury types (88%). The method can also estimate AC properties with relatively low error (thickness = 12.7% mm, equilibrium modulus = 10.7% MPa, instantaneous modulus = 11.8% MPa). These findings demonstrate the potential of MIR spectroscopy as a tool for assessment of AC integrity changes that result from injury.

Bibliographic Information

JournalAnnals of Biomedical Engineering
PublisherSpringer
Publication Date2024-09-01
Publication Year2024
Volume52
Issue9
Pages2521-2533
Document TypeJournal Article
Print ISSN0090-6964
eISSN1573-9686
DOI10.1007/s10439-024-03540-x

Access Information

NARA Access Coverage1972-01-01~Current
Journal Homepagehttps://www.springer.com/journal/10439
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.