NARA Discovery
Article Details
← Back to Search Results
Journal Article

Vascular Flow Phantom of A Cohort-Based Averaged Abdominal Aortic Aneurysm: Design, Fabrication and Characterization

H. Mirgolbabaee; J. R. Nagel; J. Plomp; A. Ghanbarzadeh-Dagheyan; J. A. Simmering; M. Versluis; M. M. P. J. Reijnen; E. Groot Jebbink
Annals of Biomedical Engineering · Vol. 53, Issue 6 · pp. 1439-1452 · 2025

Abstract

Purpose Vascular flow phantoms are an invaluable tool for in vitro and in silico studies, but their design and fabrication processes are often not reported. In this study , a framework is introduced to design and fabricate 3D printable high-fidelity cohort-based averaged abdominal aortic aneurysm (AAA) phantoms. Methods AAA geometries of 50 patients were segmented from preoperative computed tomography angiography scans. The segmented geometries and center lumen lines (CLL) were used in an in-house developed algorithm to average the CLL coordinates and corresponding diameters over the entire cohort. The reconstructed averaged anatomy was 3D printed as a thin-walled flow phantom with Formlabs Flexible 80A resin. The acoustic properties of the resin were characterized and the feasibility of flow field quantification inside the phantom with ultrasound particle imaging velocimetry (echoPIV) was investigated. Results Comparison between patient-specific models generated by our method and their corresponding reference segmentations, for ten patients, showed a mean Sørensen–Dice similarity coefficient of 0.916 ± 0.21 and the largest distances (5-10% of the lumen diameter) were found at the aneurysmal sac. The Flexible 80A resin had an average speed of sound of 1785 m/s, attenuation of 7.8 dB/mm and density of 1130 kg/m 3 . Volumetric flow profiles obtained with echoPIV in the suprarenal artery (i.e. phantom inlet) matched the flow sensor data. Conclusion The reported framework was used to make an averaged, cohort-based AAA model, which showed a good match with its reference model. A 3D printed, thin-walled phantom was made based on this model and the feasibility of flow field quantification inside the phantom was shown.

Bibliographic Information

JournalAnnals of Biomedical Engineering
PublisherSpringer
Publication Date2025-06-01
Publication Year2025
Volume53
Issue6
Pages1439-1452
Document TypeJournal Article
Print ISSN0090-6964
eISSN1573-9686
DOI10.1007/s10439-025-03717-y

Access Information

NARA Access Coverage1972-01-01~Current
Journal Homepagehttps://www.springer.com/journal/10439
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.