NARA Discovery
Article Details
← Back to Search Results
Journal Article

Location-Specific Comparison Between a 3D In-Stent Restenosis Model and Micro-CT and Histology Data from Porcine In Vivo Experiments

P. S. Zun; A. J. Narracott; C. Chiastra; J. Gunn; A. G. Hoekstra
Cardiovascular Engineering and Technology · Vol. 10, Issue 4 · pp. 568-582 · 2019

Abstract

Background Coronary artery restenosis is an important side effect of percutaneous coronary intervention. Computational models can be used to better understand this process. We report on an approach for validation of an in silico 3D model of in-stent restenosis in porcine coronary arteries and illustrate this approach by comparing the modelling results to in vivo data for 14 and 28 days post-stenting. Methods This multiscale model includes single-scale models for stent deployment, blood flow and tissue growth in the stented vessel, including smooth muscle cell (SMC) proliferation and extracellular matrix (ECM) production. The validation procedure uses data from porcine in vivo experiments, by simulating stent deployment using stent geometry obtained from micro computed tomography (micro-CT) of the stented vessel and directly comparing the simulation results of neointimal growth to histological sections taken at the same locations. Results Metrics for comparison are per-strut neointimal thickness and per-section neointimal area. The neointimal area predicted by the model demonstrates a good agreement with the detailed experimental data. For 14 days post-stenting the relative neointimal area, averaged over all vessel sections considered, was 20 ± 3% in vivo and 22 ± 4% in silico . For 28 days, the area was 42 ± 3% in vivo and 41 ± 3% in silico . Conclusions The approach presented here provides a very detailed, location-specific, validation methodology for in silico restenosis models. The model was able to closely match both histology datasets with a single set of parameters. Good agreement was obtained for both the overall amount of neointima produced and the local distribution. It should be noted that including vessel curvature and ECM production in the model was paramount to obtain a good agreement with the experimental data.

Bibliographic Information

JournalCardiovascular Engineering and Technology
PublisherSpringer
Publication Date2019-12-01
Publication Year2019
Volume10
Issue4
Pages568-582
Document TypeJournal Article
Print ISSN1869-408X
eISSN1869-4098
DOI10.1007/s13239-019-00431-4

Access Information

NARA Access Coverage2010-01-01~Current
Journal Homepagehttps://www.springer.com/journal/13239
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.