NARA Discovery
Article Details
← Back to Search Results
Journal Article

Importance of Preserved Tricuspid Valve Function for Effective Soft Robotic Augmentation of the Right Ventricle in Cases of Elevated Pulmonary Artery Pressure

Isaac Wamala; Christopher J. Payne; Mossab Y. Saeed; Daniel Bautista-Salinas; David Van Story; Thomas Thalhofer; Steven J. Staffa; Sunil J. Ghelani; Pedro J. del Nido; Conor J. Walsh; Nikolay V. Vasilyev
Cardiovascular Engineering and Technology · Vol. 13, Issue 1 · pp. 120-128 · 2022

Abstract

Purpose In clinical practice, many patients with right heart failure (RHF) have elevated pulmonary artery pressures and increased afterload on the right ventricle (RV). In this study, we evaluated the feasibility of RV augmentation using a soft robotic right ventricular assist device (SRVAD), in cases of increased RV afterload. Methods In nine Yorkshire swine of 65–80 kg, a pulmonary artery band was placed to cause RHF and maintained in place to simulate an ongoing elevated afterload on the RV. The SRVAD was actuated in synchrony with the ventricle to augment native RV output for up to one hour. Hemodynamic parameters during SRVAD actuation were compared to baseline and RHF levels. Results Median RV cardiac index (CI) was 1.43 (IQR, 1.37–1.80) L/min/m 2 and 1.26 (IQR 1.05–1.57) L/min/m 2 at first and second baseline. Upon PA banding RV CI fell to a median of 0.79 (IQR 0.63–1.04) L/min/m 2 . Device actuation improved RV CI to a median of 0.87 (IQR 0.78–1.01), 0.85 (IQR 0.64–1.59) and 1.11 (IQR 0.67–1.48) L/min/m 2 at 5 min ( p = 0.114), 30 min ( p = 0.013) and 60 ( p = 0.033) minutes respectively. Statistical GEE analysis showed that lower grade of tricuspid regurgitation at time of RHF ( p = 0.046), a lower diastolic pressure at RHF ( p = 0.019) and lower mean arterial pressure at RHF ( p = 0.024) were significantly associated with higher SRVAD effectiveness. Conclusions Short-term augmentation of RV function using SRVAD is feasible even in cases of elevated RV afterload. Moderate or severe tricuspid regurgitation were associated with reduced device effectiveness.

Bibliographic Information

JournalCardiovascular Engineering and Technology
PublisherSpringer
Publication Date2022-02-01
Publication Year2022
Volume13
Issue1
Pages120-128
Document TypeJournal Article
Print ISSN1869-408X
eISSN1869-4098
DOI10.1007/s13239-021-00562-7

Access Information

NARA Access Coverage2010-01-01~Current
Journal Homepagehttps://www.springer.com/journal/13239
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.