NARA Discovery
Article Details
← Back to Search Results
Journal Article

Validation of pharmacokinetic model for quizartinib quantified by UPLC-MS/MS in patients with FLT3-ITD negative newly diagnosed acute myeloid leukemia

Antonio Solana-Altabella; Carles Iniesta-Navalón; Maria Chovi-Trull; Rebeca Rodriguez-Veiga; Marina Lopez-Nogueroles; David Martínez-Cuadrón; Mayte Gil-Candel; Laura Torres-Miñana; Evelyn Acuña-Cruz; Isabel Cano-Ferri; Blanca Boluda; Irene Navarro-Vicente; Pilar Lloret-Madrid; Eva Barragán; Jose Vicente Gil; Mario Rodenas-Rovira; Juan Eduardo Megías-Vericat; Jorge Labrador; José Esteban Peris-Ribera; Jose Luis Poveda-Andrés; Pau Montesinos
European Journal of Clinical Pharmacology · Vol. 81, Issue 11 · pp. 1699-1709 · 2025

Abstract

Purpose Quizartinib pharmacokinetics in FLT3-ITD negative acute myeloid leukemia (AML) remain largely unexplored. This study aims to validate a population pharmacokinetics model (popPK) for quizartinib in plasma samples of FLT3-ITD negative AML patients. To do so, an ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated for the quantification of quizartinib. Methods Plasma samples were collected from FLT3-ITD negative newly diagnosed AML patients undergoing quizartinib therapy at induction in the QUIWI phase II clinical trial [NCT04107727, PETHEMA group] between March 2020 and February 2022. The UPLC-MS/MS method was developed and validated. A previously described popPK model was validated using external validation techniques and implemented using the software NONMEM v7.5. Results The developed UPLC-MS/MS method demonstrated high accuracy and precision with a linear range of 6 to 200 ng/mL, with relative standard deviation between 3–11 and accuracy of 88–97% from nominal values. The external validation of the quizartinib popPK model showed minimal bias at the population level (MdPE: -9.86%; ME: 0.50 ng/mL, p = 0.964), but moderate imprecision (MdAPE: 32.28%) and suboptimal accuracy (F20: 24.5%; F30: 43.4%). Individual predictions improved performance, with negligible bias (MdPE: -0.50%), acceptable precision (MdAPE: 11.27%), and F20 (64.2%) and F30 (77.4%) exceeding predefined thresholds. Visual predictive checks confirmed adequate prediction of median concentrations, though some deviations occurred at extremes. Conclusion This study presents a replicable UPLC-MS/MS method for the determination of quizartinib in plasma. The validated popPK model can be used to optimize dosing strategies in future clinical studies.

Bibliographic Information

JournalEuropean Journal of Clinical Pharmacology
PublisherSpringer
Publication Date2025-11-01
Publication Year2025
Volume81
Issue11
Pages1699-1709
Document TypeJournal Article
Print ISSN0031-6970
eISSN1432-1041
DOI10.1007/s00228-025-03909-4

Access Information

NARA Access Coverage1968-01-01~Current
Journal Homepagehttps://www.springer.com/journal/228
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.