NARA Discovery
Article Details
← Back to Search Results
Journal Article

Performance of the BD Phoenix CPO detect assay for detection and classification of carbapenemase-producing organisms

Laura Berneking; Anna Both; Benjamin Berinson; Armin Hoffmann; Marc Lütgehetmann; Martin Aepfelbacher; Holger Rohde
European Journal of Clinical Microbiology & Infectious Diseases · Vol. 40, Issue 5 · pp. 979-985 · 2021

Abstract

Increasing worldwide, prevalence of carbapenem-resistant gram-negative bacteria demands urgent a need for rapid detection and accurate identification of carbapenemases. The BD Phoenix CPO detect (PCD) assay possesses an in-built capacity for parallel susceptibility testing and detection of carbapenemases. Here, the ability of the assay to detect and classify carbapenemase production was tested in a collection of carbapenem-resistant Enterobacterales and non-fermentative gram-negative rods. The ability of the PCD assay to detect and classify carbapenemases was investigated in a collection of 194 clinical, carbapenem-resistant isolates ( Enterobacterales [ n = 65]; non-fermentative gram-negative rods [ n = 129]). AST results were compared to MICS determined by gradient diffusion to determine accuracy of the PCD assay. The accuracy of the PCD assay to detect carbapenemases was compared to the results of molecular isolate characterization using a LDT multiplex carbapenemase PCR assay. All 194 isolates classified as carbapenem-resistant by reference susceptibility testing were also classified correctly as CRO by the PCD assay. Performance analysis of the PCD assay to detect carbapenemase production revealed an overall sensitivity of 98.29% and specificity of 17.95% for the detection of carbapenemase production. For the classification of carbapenemases classes A, B, and D, the PCD correctly classified 79.17% Enterobacterales and 67.16% non-fermentative gram-negative rods. The PCD assay is a reliable tool for the detection of carbapenem resistance and allows for parallel analysis of carbapenemase production. However, while sensitivity is high, low specificity in carbapenemase detection and erroneous classification demands mandatory confirmation by alternative methods, especially in non-fermentative gram-negative bacteria.

Bibliographic Information

JournalEuropean Journal of Clinical Microbiology & Infectious Diseases
PublisherSpringer
Publication Date2021-05-01
Publication Year2021
Volume40
Issue5
Pages979-985
Document TypeJournal Article
Print ISSN0934-9723
eISSN1435-4373
DOI10.1007/s10096-020-04094-1

Access Information

NARA Access Coverage1982-01-01~Current
Journal Homepagehttps://www.springer.com/journal/10096
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.