NARA Discovery
Article Details
← Back to Search Results
Journal Article

Bicycle spiroergometry: comparison of standardized examination protocols for adolescents: is it necessary to define own standard values for each protocol?

Jana Windhaber; Monica Steinbauer; Magdalena Holter; Annemarie Wieland; Kristina Kogler; Regina Riedl; Peter Schober; Christoph Castellani; Georg Singer; Holger Till
European Journal of Applied Physiology · Vol. 121, Issue 6 · pp. 1783-1794 · 2021

Abstract

Purpose To compare performance data of adolescents collected with five different bicycle spiroergometry protocols and to assess the necessity for establishing standard values for each protocol. Methods One-hundred-twenty adolescents completed two bicycle spiroergometries within 14 days. One of the two tests was performed based on our institutional weight-adapted protocol (P0). The other test was performed based on one out of four exercise protocols widely used for children and adolescents (P1, 2, 3 or 4) with 30 persons each. The two tests were performed in a random order. Routine parameters of cardiopulmonary exercise tests (CPET) such as VO 2 peak, maximum power, O 2 pulse, OUES, VE/VCO 2 slope as well as ventilatory and lactate thresholds were investigated. Agreement between protocols was evaluated by Bland–Altman analysis, coefficients of variation (CV) and intra-class correlation coefficients (ICC). Results None of the CPET parameters were significantly different between P0 and P1, 2, 3 or 4. For most of the parameters, low biases between P0 and P1–P4 were found and 95% confidence intervalls were narrow. CV and ICC values largely corresponded to well-defined analytical goals (CV < 10% and ICC > 0.9). Only maximal power (Pmax) showed differences in size and drift of the bias depending on the length of the step duration of the protocols. Conclusion Comparability between examination protocols has been shown for CPET parameters independent on step duration. Protocol-dependent standard values do not appear to be necessary. Only Pmax is dependent on the step duration, but in most cases, this has no significant influence on the fitness assessment.

Bibliographic Information

JournalEuropean Journal of Applied Physiology
PublisherSpringer
Publication Date2021-06-01
Publication Year2021
Volume121
Issue6
Pages1783-1794
Document TypeJournal Article
Print ISSN1439-6319
eISSN1439-6327
DOI10.1007/s00421-021-04601-y

Access Information

NARA Access Coverage1928-01-01~Current
Journal Homepagehttps://www.springer.com/journal/421
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.