NARA Discovery
Article Details
← Back to Search Results
Journal Article

Multicenter evaluation of the QuickMIC® rapid AST system in clinical practice: impact on turnaround time compared to routine AST systems

Anna Olsson; Alexandra Rafeletou; Amanda Åman; Nicolette Athanasiou; Celia García-Rivera; Derek Gerstbrein; Brian Mesich; Logan Patterson; Julia Vahturova; Nicole VanZeeland; Andrea Ricart-Silvestre; Matthew L. Faron; Jessica Hoff; Kevin Alby; Marina Ivanova; Juan Carlos Rodríguez Díaz; Cecilia Johansson; Christer Malmberg
European Journal of Clinical Microbiology & Infectious Diseases · Vol. 45, Issue 1 · pp. 185-196 · 2026

Abstract

Increased antibiotic resistance highlights the need for new, rapid antibiotic susceptibility tests to guide therapy, especially in critical disease such as bloodstream infections and sepsis. This study investigates a new ultra-rapid AST system in multiple clinical laboratories, with respect to accuracy, speed and turnaround time in comparison to commonly used AST systems. The QuickMIC system is compared to the commonly used automated AST systems BD Phoenix™ (BD, USA), MicroScan WalkAway plus (Beckman Coulter, USA) and VITEK ® 2 (bioMérieux, France) by concurrent testing of incoming positive blood-cultures with Gram-negative bacteria in four clinical laboratories located in the EU and USA, on the basis of agreement of results, time-to-result (TTR, analysis time) and turnaround time (TAT, time from blood culture positivity or blood culture processing to actionable result). A total of 155 patient samples were included, totaling 10 species of Gram-negative bacteria. The overall EA and CA between QuickMIC ® GN and each routine AST system was > 95%, while overall bias was within the acceptable range of ± 30%. QuickMIC time-to-result was on average 3 h and 4 min, compared to 9–19 h for the routine systems. The average QuickMIC system turnaround-time ranged from 10 to 11 h 30 min, compared to 22–45 h for the routine systems. The QuickMIC system represents a promising rapid AST technology with potential to reduce time-to-result and overall turnaround-time of clinically actionable AST results compared with the most common routinely used automated AST methods, while maintaining good accuracy and quality of results.

Bibliographic Information

JournalEuropean Journal of Clinical Microbiology & Infectious Diseases
PublisherSpringer
Publication Date2026-01-01
Publication Year2026
Volume45
Issue1
Pages185-196
Document TypeJournal Article
Print ISSN0934-9723
eISSN1435-4373
DOI10.1007/s10096-025-05298-z

Access Information

NARA Access Coverage1982-01-01~Current
Journal Homepagehttps://www.springer.com/journal/10096
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.