NARA Discovery
Article Details
← Back to Search Results
Journal Article

Skeletal muscle microvascular and respiratory responses to exercise in healthy and T2D adults: agreement and reproducibility study of NIRS technologies

Adam A. Luco; Martin Gram; Inge Ramakers; Terence Ryan; Osvaldo Enriquez; James Faulkner; Lee Stoner; David S. Rowlands
European Journal of Applied Physiology · 2026

Abstract

Introduction Continuous wave (CW) near-infrared spectroscopy (NIRS) is widely used in skeletal muscle tissue hemodynamic and respiratory research utilizing fixed light scattering assumptions. Purpose Compare reproducibility and technical characteristics of CW-NIRS against frequency-domain (FD)-NIRS, which allows for intra-individual scattering correction. Methods Muscle blood flow (mBF) and oxygen uptake ( $${\text{m}\dot{\text{V}}\text{O}}_{2}$$ ) (using rapid-occlusions), and perfusion were assessed with NIRS in 10 healthy (ND) and 10 type-2 diabetic (T2D) men at rest and during knee extensions at 5% and 15% of maximal voluntary contraction (MVC) on three occasions within 10 days. Results In both groups, exercise responses for mBF and $${\text{m}\dot{\text{V}}\text{O}}_{2}$$ were not substantially different between technology with moderate-high between-day reproducibility (ICC range 0.72–0.98). However, compared to FD-NIRS, CW-NIRS perfusion substantially higher at rest (21 uM; 90%CI 29–13), 5%MVC (18 uM; 27–9) and 15%MVC (17 uM; 26–8) in T2D, but not ND. Standardized typical errors during exercise were small-moderate: e.g., 15%MVC mBF, CW-NIRS (ND 0.45; T2D 0.49), FD-NIRS (0.35; 0.49); mV̇O 2 , CW-NIRS (0.24; 0.26), FD-NIRS (0.45; 0.32); perfusion CW-NIRS (0.25; 0.25) and FD-NIRS (0.25; 0.23); and, not different between groups and technology. Conclusion Both NIRS technologies are reproducible. CW-NIRS assumptions work for muscle blood flow and oxygen use at rest and during exercise. FD-NIRS might be better at detecting changes in perfusion during exercise, especially in older or clinical groups. However, FD-NIRS is more expensive and complex, making it less practical.

Bibliographic Information

JournalEuropean Journal of Applied Physiology
PublisherSpringer
Publication Date2026-06-29
Publication Year2026
Document TypeJournal Article
Print ISSN1439-6319
eISSN1439-6327
DOI10.1007/s00421-026-06300-y

Access Information

NARA Access Coverage1928-01-01~Current
Journal Homepagehttps://www.springer.com/journal/421
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.