NARA Discovery
Article Details
← Back to Search Results
Journal Article

Spectrofluorimetric Approach for Quantification of Cyclizine in the Presence of its Toxic Impurities in Human Plasma; in silico Study and ADMET Calculations

Michel Y. Fares; Nada S. Abdelwahab; Ghada M. El-Sayed; Maha A. Hegazy; Maha M. Abdelrahman
Journal of Fluorescence · Vol. 32, Issue 3 · pp. 993-1003 · 2022

Abstract

Cyclizine (CYZ); an antiemetic compound; is widely misused for its euphoric or hallucinatory effects, either by oral or intravenous routes. The concomitant abuse of CYZ among addicted adolescents contributes to neuromuscular disorders that are life-threatening. Consequently, with the company of 1-Methylpiperazine (MPZ) and diphenylmethanol (DPM, Benzhydrol) as pharmacopoeia-reported CYZ impurities, a novel spectrofluorimetric assay for the detection of CYZ, has been established either in human plasma samples or in its parenteral formulation. The native fluorescence of CYZ has been investigated under various conditions. Different parameters affecting relative fluorescence intensity of CYZ including diluting solvent, surfactant, plasma protein solvent, and pH were studied and optimized. The linearity obtained between the fluorescence intensity at emission wavelength 350 nm after excitation at 244 nm and the corresponding CYZ concentrations was in the range 10–1000 ng/mL for measurement of CYZ either in pure form or in human plasma samples, with a appropriate correlation coefficient (r = 0.9999) and 3.10 ng/mL as the limit of detection and 9.41 ng/mL as the limit of quantitation. The suggested procedure was created and validated in accordance with ICH guidelines for quantification of CYZ either in its pure form or its dosage form, and FDA guidelines for the assay of CYZ in human plasma. Finally, in silico study and ADMET predictions were conducted for the studied drug impurities to estimate their pharmacokinetic behaviors. The results showed that both CYZ impurities have higher cellular permeability and maximum tolerated doses, DPM has higher BBB and CNS permeability than MPZ, while MPZ exceeds DPM in total clearance and volume of distribution. Graphic Abstract

Bibliographic Information

JournalJournal of Fluorescence
PublisherSpringer
Publication Date2022-05-01
Publication Year2022
Volume32
Issue3
Pages993-1003
Document TypeJournal Article
eISSN1573-4994
DOI10.1007/s10895-022-02897-3

Access Information

NARA Access Coverage1991-01-01~Current
Journal Homepagehttps://www.springer.com/journal/10895
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.