NARA Discovery
Article Details
← Back to Search Results
Journal Article

Measuring Heterogeneity in 18F-Fluorodeoxyglucose Positron Emission Tomography Images for Classifying Metastatic and Benign Bone Lesions in Patients with Cervical Cancer

Feng-Yuan Liu; Gigin Lin; Jing-Ren Tseng; Angel Chao; Huei-Jean Huang; Hung-Hsueh Chou; Yu-Chen Chang; Tzu-Chen Yen; Chyong-Huey Lai
Journal of Medical and Biological Engineering · Vol. 41, Issue 6 · pp. 924-933 · 2021

Abstract

Purpose Heterogeneity assessment can be applied for medical imaging analysis. Here, we evaluated first-order and texture analysis (TA) metrics in 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography (PET) imaging for classification of metastatic and benign bone lesions in patients with cervical cancer. Methods The data of 18 F-FDG PET studies performed on a specific PET/CT system from 2016 to 2018 in patients with cervical cancer were retrieved. The data of bone lesions extracted from studies over 2016–2017 and 2018 were used as training and validation datasets, respectively. Metastatic bone lesions were identified in each dataset, with an equal number of benign bone lesions selected. Cuboid volume of interest (VOI) consisting of 3 × 3 × 5 reconstructed voxels was applied for first-order metrics, and cubic VOI consisting of smaller voxels with trilinear interpolation of standardized uptake value (SUV) was adopted for TA metrics. First-order metrics included the maximum SUV (SUVmax) of lesions and the mean voxel SUV and its standard deviation (SUVsd), skewness, and kurtosis in VOI. In total, 4464 TA metrics based on 62 texture features were evaluated. Logistic regression was used for classification with area under the receiver operating characteristic curve (AUC) as the performance measure. Results From the training and validation datasets, 98 and 42 metastatic bone lesions were identified, respectively. SUVsd demonstrated higher performance than did SUVmax in both the training (AUC .798 vs .732, P = .001) and validation (AUC .786 vs .684, P < .001) datasets. Top-performing TA metrics demonstrated significantly higher performance in the training dataset, but not in the validation dataset. Conclusion A simple first-order measure of heterogeneity, SUVsd, was found to be superior to SUVmax for the classification of metastatic and benign bone lesions. Multiple hypothesis testing can result in false-positive findings in TA with multiple features and parameters; careful validation is required.

Bibliographic Information

JournalJournal of Medical and Biological Engineering
PublisherSpringer
Publication Date2021-12-01
Publication Year2021
Volume41
Issue6
Pages924-933
Document TypeJournal Article
Print ISSN1609-0985
eISSN2199-4757
DOI10.1007/s40846-021-00671-7

Access Information

NARA Access Coverage2015-01-01~Current
Journal Homepagehttps://www.springer.com/journal/40846
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.