NARA Discovery
Article Details
← Back to Search Results
Journal Article

A Finite Element Analysis Comparing an Additive Manufacturing Lattice-Structured PEEK Implant to a Commercial Ball-and-Socket Design for Cervical Total Disc Replacement

Ming-Kai Hsieh; Fu-Cheng Kao; Yun-Da Li; De-Mei Lee; Hui Jin; Ching-Lung Tai; Tsung-Ting Tsai; Po-Liang Lai; Weng-Pin Chen
Journal of Medical and Biological Engineering · Vol. 45, Issue 1 · pp. 112-126 · 2025

Abstract

Purpose Cervical total disc replacement (TDR) is commonly performed to treat degenerative cervical spondylosis, but it often faces challenges such as implant wear and migration. This study aimed to develop and evaluate a novel 3D-printed TDR featuring a titanium endplate and a lattice-structured poly-ether-ether-ketone (PEEK) design. The primary objective was to replicate the natural motion of the cervical disc while addressing complications associated with conventional TDRs. Methods The novel implant was created using additive manufacturing techniques, incorporating three lattice-structured PEEK designs (Cross, Octet, and Ventiles) for the nucleus pulposus and annulus fibrosus components. A finite element analysis was conducted to compare the biomechanical performance of the novel TDR with an intact cervical disc and a commercially available TDR (Baguera®C, Spineart SA, Geneva, Switzerland). Key parameters, including maximal von Mises stresses, range of motion, paths of the instantaneous center of rotation, and facet joint stresses, were evaluated under physiological loads (100 N follower load and 1.5 Nm pure moments). Results The novel 3D-printed TDR maintained structural integrity, with stresses remaining within the yield strength of PEEK. The biomechanical performance closely resembled that of an intact cervical disc, demonstrating similar ranges of motion, instantaneous center of rotation paths, and facet joint stress distributions. Conclusion The findings indicate that the innovative 3D-printed TDR may restore normal cervical spinal kinematics more effectively than existing commercial options, potentially reducing the risk of post-operative facet joint syndrome. Further experimental and clinical studies are recommended to validate these results.

Bibliographic Information

JournalJournal of Medical and Biological Engineering
PublisherSpringer
Publication Date2025-02-01
Publication Year2025
Volume45
Issue1
Pages112-126
Document TypeJournal Article
Print ISSN1609-0985
eISSN2199-4757
DOI10.1007/s40846-024-00925-0

Access Information

NARA Access Coverage2015-01-01~Current
Journal Homepagehttps://www.springer.com/journal/40846
Publisher PageOpen Publisher Page
Full-text access depends on NARA's subscribed coverage and institutional access.